หมวดหมู่

CT1O Outdoor CO2 Sensor Senva Inc

Dual Analog 3wire 420mA and 05V/010V (2) (dip switch selectable) Output scaling CO2 0 2000 (default) or 0 5000/10000 ppm (selectable) Output Scaling Temp 32 to 122oF (050oC) or 40 to 140oF (4060oC) (Switch Selectable) Digital Setpoint Output Programmable Solidstate, 1A 30VAC/DC, mance Type Nondispersive Infrared (NDIR) Accuracy


22DC51/3 Series | Belimo Duct Air Quality Sensor CO2 ...

The Belimo Duct Air Quality sensors actively measure CO2 with 0 to 10 V or 4 to 20 mA output signal. Other models available with additional temperature/humidity, or temperature/VOC sensors integrated in one device. All models offer NDIR (nondispersive infrared) sensor technology with dual channel calibration housed in a NEMA4X / IP65 rated enclosure.


CO2 Sensor Kele

Dual Analog 3wire 420mA and 05V/010V (2) (jumper) Output scaling 0 2000 or 0 5000 ppm (selectable) Digital Setpoint Output Programmable Solidstate, 1A 30VAC/DC, Sensor Performance Type Nondispersive Infrared (NDIR) Accuracy ±40ppm, ±3% of reading Response time 2 minutes to 90% reading Output update rate 3 seconds


アナログ(0~10V、0~5V、1~5Vなど)をアナログ(4~20mA、0…

をいて、0~5v、1~5v、0~10vなどのアナログを4~20ma、0~20maなどのアナログにできます。 のにより、するやするをすることもです。 ・k3fpvs ()


CO2VAL Recessed Wall Value CO2 Sensor

CO2VAL Series ORDERING CO2VAL Value CO2 DIMENSIONS To order replacement sensor elements, please consult factory SPECIFICATIONS Power Supply 1230VDC/24VAC(1), 100mA max. Analog Outputs Dual Analog 3wire 420mA and 05V/010V(2) (dip switch selectable) Output scaling 0 2000 ppm Sensor Performance Type Nondispersive Infrared (NDIR)


ACI 147584 Carbon Dioxide Sensor, Room, 02000 PPM (05V ...

The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non dispersive infrared technology and is a cost efficient solution for measuring carbon dioxide (CO2) levels for building climate control. In addition, ABC software eliminates the need for manual calibration.


ENVIRONMENTAL SENSORS INSTALLATION GUIDE

• Turn off all power supplying equipment before working on it. 05V/010V output; HD transmitter accuracy: ±°C (±°F) typical Operating Environment: Operating Humidity Range 0 to RH noncondensing Operating Temperature Range 40° to 50°C (40° to 122°F) Agency Approvals EMC EN 500811, EN 500821, EN 6100044, EN 6100045,


CO Sensor AAON

010V 010V 010V 010V 010V 010V 05V 05V 05V 05V 05V 05V AI5 AI7 ANALOG INPUT JUMPER SETTINGS WattMaster Label LB10207301A Rev.: 1A VCMX MODULAR EBUS CONTROLLER Orion No.:OE33223EVCMXMODA AAON No.: V07150 AI1 = SPC (SPACE TEMPERATURE SENSOR) AI2 AI3 AI4 AI5 AI7 A01 A02 = …


IAQ1000 : Indoor Air Quality Transmitter | Omicron ...

CO2 — CO2sensor: Dual Beam NDIR. Range: 03,000 ppm. Output: RS485 Modbus and Analog Output (05V , 010V,420mA) Accuracy: ±70 ppm or ±5% of reading


SwiftOne : IoT ระบบ IoT เซ็นเซอร์ Sensors และ Facility ...

Wireless 2Input 05V ADC Sampling Interface (powered by 2 x ER14505 Lithium AA battery) 39: Wireless 010V ADC Sampling Interface (powered by 2 x ER14505 Lithium AA battery) 40: Wireless 2Input 010V ADC Sampling Interface (powered by 2 x ER14505 Lithium AA battery) 41


05V/010V to 0 Voltage to PWM Converter Board Duty ...

This product can transform 05V/010V voltage into 0 PWM output, and adjusting voltage can change the PWM duty cycle. It can be applied to motor control. Features: 1>.Adopt MCU embedded technique. 2>.Easy to operate, adjusting the potentiometer can achieve fine tuning.


CO2 Transmitter

New infrared calibration technology applied for CO2 concentration measurement, with high accuracy, low drift and long life. With a wide measuring range, default 05000ppm, with temperature compensation and little influence by temperature. 420mA, 010V, 05V multiple analog signal output available.


CO2 BAPIStat "Quantum Prime" Carbon Dioxide, Temp and ...

The BAPI CO2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building’s HVAC strategy. The Single Beam unit has been optimized for periodically unoccupied areas and features Automatic Background Calibration (ABC) over a long time period to reduce drift. It includes a builtin Barometric pressure sensor that continuously compensates […]


Top Brand CO2 Sensor Carbon Dioxide Transmitter Renke

RSCO2**2 carbon dioxide sensor with rs485, 420ma, 05v, 010v output. A temperature and humidity probe can be added to the bottom of the transmitter to be used as a co2 temperature and humidity sensor while measuring the concentration of co2 gas and the temperature and humidity value of the current environment. This is a wall mounted co2 sensor that can be used in greenhouses, …


GaS SpeCialty SenSorS Kele

04580373F aSense duct relay 0 5V display CO2 Temperature sensor, relay 05080140 eSense wall 0 10V CO2 sensor 05080141 eSense wall 0 10V dispaly CO2 sensor 05080142 eSense wall 0 5V CO2 sensor 05080143 eSense wall 0 5V dispaly CO2 sensor 05080158 eSense duct 0 10V CO2 sensor 05080159 eSense duct 0 10V dispaly CO2 sensor


AirGreen|センサー|センサー(CO,CO2, …

ビニールハウスの、CO2でなCO2センサー。 キャリブレーション、の2(Dual Wavelength Method)。 は、DC4~20mA, 0~5V/0~10V。 EE820シリーズカタログ


CO2 room Tasseron Sensors and Controls

Very accurate CO2 measurement from 40010,000 ppm (CO2) and 0 (RH) with 2% accuracy. Standard versions complete with on board DIP switches that provide output signal change in the field for 05V, 010V and 420mA. Fixed analog outputs or digital BACnet or MODBUS are also available for custom orders. FEATURES. CO2 or Combination CO2/RH/Temp ...


ACI 147566 Carbon Dioxide Sensor, Room, 02000 PPM (05V ...

The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non dispersive infrared technology and is a cost efficient solution for measuring carbon dioxide (CO2) levels for building climate control. In addition, ABC software eliminates the need for manual calibration.


CO2 Sensor

Dual Analog 3wire 420mA and 05V/010V (2) (dip switch selectable) Output scaling CO2 0 2000 (default) or 0 5000/10000 ppm (selectable) Output Scaling Temp 32 to 122oF (050oC) or 40 to 140oF (4060oC) (Switch Selectable) Digital Setpoint Output Programmable Solidstate, 1A 30VAC/DC, Sensor Performance Type Nondispersive ...